Conceptually new anti-theft system
RECORDING (SAVING) KEYS IN MEMORY.
Factory default setting can be changed using the button supplied with the SNIPER. The logic button use is two-step (see. Table 1):
• The first series of clicks is for the choosing of a particular function
menu.
• The second series of clicks is entering a personal access code.
Personal code set from the factory is 5 (five button pressings). it is desirable to change the code on your own code after you get acquainted with the system (see Change of personal system code).
If you find that you missed your daily tablet key, you must use the service button to delete keys from the device memory and save the remaining (or new) keys in memory to prevent the theft. The missing key will not be able to control the device after that.
Table 1.
Description of the function |
Number of service button pressings |
Need for input of PIN-code |
Description of subfunction |
Number of service button pressings to set subfunction |
| Enabling / disabling guard mode |
2 |
Yes |
— |
— |
| Enabling / disabling service mode | 4 |
Yes |
— |
— |
| Registration of tablet key |
6 |
Yes |
— |
— |
| Deleting of all keys tablets, restoration functions to factory settings |
8 |
Yes |
— |
— |
| Change of user's PIN-code | 10 |
Yes |
— |
— |
| Setting device functions | 12 |
Yes |
Enabling / disabling stealth mode of indication |
1 - change of the current function status |
| 2 - continue to the next function | ||||
| 3 - exit setup function | ||||
Polarity reversal Automatic input switching protection regime |
1 - change the current function status | |||
| 2 - transition to the next function | ||||
| 3 - exit setup function |
REMOVING KEYS FROM THE DEVICE MEMORY.
Initial state - the device is not in guard mode (LED is lit).
• 8 short pressings.
• Pause for 2-3 seconds.
• Permanent indicator light (5 seconds to get ready for receiving a code, if the code is not entered the indicator flashes 5 times after a short pause. The indicator is on and the devise is reset to the initial state).
• Personal code (factory code is 5 button pressings).
• Permanent lite for 7 seconds.
• A short pause for 2 seconds.
• 1 or 2 indicator flashes according to the number of tablet keys with access.
• No light - the keys are removed from the device memory.
The graph of correspondence the moment of pressing button and the LED status during removing keys from the device memory.
RECORDING (SAVING) KEYS IN MEMORY.
The device is not in the guard mode in the initial state (LED is not lit).
• 6 short pressings.
• Pause for 2-3 seconds.
• Permanent indicator light (5 seconds to get ready for receiving a code, if the code is not entered the indicator flashes 5 times after a short pause. The indicator is on and the devise is reset to the initial state).
• Personal code (factory code is 5 button pressings).
• Permanent light for 7 seconds.
• A short pause for 2 seconds.
• Frequent blinking. Press the recorded key to the socket and remove.
• 1 flash of LED is a confirmation that the key is saved.
The graph of correspondence the moments of pressing button and the LED status during saving keys in the device memory.